John Deere 450DLC — Travel Speed Solenoid Valve (port SI) Test and Adjustment

TM2361 (24JUN08) 9025-25-22 450DLC Excavator Operation and Tests 062608 PN=882 Tests 7. Actuate travel function to full forward or reverse. Record pressure readings from monitor and gauge. 8. Calculate the pressure range using the calculated reading from monitor and the specify tolerance. Check that the actual reading from gauge is within the pressure range. Specification Travel Speed Solenoid Valve (port SI)—Pressure......................................... Monitor Reading ± 0.2 MPa Monitor Reading ± 200 kPa Monitor Reading ± 2.0 bar Monitor Reading ± 29.0 psi Actual Reading From Gauge Must Be Within Pressure Range of Monitor Reading and Tolerance.

Example of Calculated Reading From Monitor Actuated Neutral Example of 3.92 MPa 0.00 MPa Calculated Reading 3920 kPa 0000 kPa From Monitor 39.2 bar 00.0 bar 569.0 psi 000 psi 9025 25 22 Continued on next page LD30992,00002B2 –19–05JUN06–4/5 Example of Calculated Reading From Monitor Actuated Neutral Example of Calculated Reading From Monitor 3.92 MPa 3920 kPa 39.2 bar 569.0 psi 0.00 MPa 0000 kPa 00.0 bar 000 psi