Tests 14. Loosen 30 mm nut (2). 15. Actuate the arm in function over relief. 16. Turn the first adjusting plug (1) out to decrease pressure to get the specified pressure for main relief valve. Specification First Adjusting Plug—Pressure Change 4.5 MPa approximate per 1/4 turn ................................................. 4500 kPa approximate per 1/4 turn 45 bar approximate per 1/4 turn 655 psi approximate per 1/4 turn 17. Hold first adjusting plug. Tighten 30 mm nut to specification. Specification 30 mm Nut—Torque 59 ....................................................................... 45 lb-ft 18. Check the pressure settings again.
LD30992,0000280 –19–05JUN06–6/6 9025 25 36 TM2361 (24JUN08) 9025-25-36 450DLC Excavator Operation and Tests 062608 PN=896