John Deere 450DLC — Test and Adjustment

TM2361 (24JUN08) 9025-25-42 450DLC Excavator Operation and Tests 062608 PN=902 Tests Boom Mode Relief Valve Test and Adjustment SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Boom Mode Switch Position On Boom Mode Relief Valve 12—13 MPa Pressure 12 000—13 000 kPa 120—130 bar 1740—1885 psi Boom Mode Relief Valve 2.1 MPa approximate per 1/4 turn Adjusting Plug Pressure Change 2100 kPa approximate per 1/4 turn 21 bar approximate per 1/4 turn 300 psi approximate per 1/4 turn SERVICE EQUIPMENT AND TOOLS JT02156A Digital Pressure/Temperature Analyzer JT02160 Transducer, 70 000 kPa (700 bar) (10,000 psi) 4200465 (1/4 M BSPP ORB x 7/16-20 M 37°) Adapter 70 000 kPa (700 bar) (10,000 psi) Gauge The purpose of boom mode relief valve is to limit the boom down force so front of machine is only lifted slightly off the ground during grading operation.

The purpose of test and adjustment is to test the pressure setting of boom 9025 25 42 mode relief valve and adjust it to the specified pressure. See Boom Mode Circuit Operation for more information.

(Group 9025-05.) Continued on next page OUT3035,0000008 –19–06JUN06–1/4 SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Boom Mode Switch Position On Boom Mode Relief Valve Pressure 12—13 MPa 12 000—13 000 kPa 120—130 bar 1740—1885 psi Boom Mode Relief Valve Adjusting Plug Pressure Change 2.1 MPa approximate per 1/4 turn 2100 kPa approximate per 1/4 turn 21 bar approximate per 1/4 turn 300 psi approximate per 1/4 turn SERVICE EQUIPMENT AND TOOLS JT02156A Digital Pressure/Temperature Analyzer JT02160 Transducer, 70 000 kPa (700 bar) (10,000 psi) 4200465 (1/4 M BSPP ORB x 7/16-20 M 37°) Adapter 70 000 kPa (700 bar) (10,000 psi) Gauge