TM2361 (24JUN08) 9025-25-46 450DLC Excavator Operation and Tests 062608 PN=906 Tests Pump Servo Piston Minimum Flow Test and Adjustment SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position P Mode Auto Idle Switch Position Off Boom Mode Switch Position Off Travel Speed Switch Position Slow (Turtle) Pump Servo Piston Minimum 48—52 sec. at slow speed with Flow Cycle Time track raised for one revolution from a running start Pump Servo Piston Minimum 4 sec.
approximate per 1/4 turn Flow Cycle Time Change Pump 1 Servo Piston Minimum 6.9 L/min approximate per 1/4 Flow Using a Flow Meter Flow turn Rate Change 1.79 gpm approximate per 1/4 turn Pump 2 Servo Piston Minimum 6.7 L/min approximate per 1/4 Flow Using a Flow Meter Flow turn Rate Change 1.77 gpm approximate per 1/4 turn The purpose of check is to test and adjust the minimum flow rate of pumps using the cycle time for travel as an indicator of pump flow rate. See Pump 1 and 2 Regulator Operation for operation of regulator and servo piston. (Group 9025-05.) 9025 25 46 Minimum flow rate can also be check using a flow meter.
See Pump Flow Test for instruction to connect flow meter to the pumps. (Group 9025-25.) 1. Adjust track sag to specification. See Check and Adjust Track Sag. (Operator’s Manual.) 2. Heat hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) Specification Hydraulic Oil—Temperature........................................................
45—55°C 110—130°F Continued on next page OUT3035,0000037 –19–19APR06–1/2 SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position P Mode Auto Idle Switch Position Off Boom Mode Switch Position Off Travel Speed Switch Position Slow (Turtle) Pump Servo Piston Minimum Flow Cycle Time 48—52 sec. at slow speed with track raised for one revolution from a running start Pump Servo Piston Minimum Flow Cycle Time Change 4 sec.
approximate per 1/4 turn Pump 1 Servo Piston Minimum 6.9 L/min approximate per 1/4 Flow Using a Flow Meter Flow Rate Change turn 1.79 gpm approximate per 1/4 turn Pump 2 Servo Piston Minimum 6.7 L/min approximate per 1/4 Flow Using a Flow Meter Flow Rate Change turn 1.77 gpm approximate per 1/4 turn