John Deere 450DLC — Maximum Flow Test and Adjustment

TM2361 (24JUN08) 9025-25-48 450DLC Excavator Operation and Tests 062608 PN=908 Tests Pump Servo Piston Maximum Flow Test and Adjustment SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Boom Mode Switch Position Off Travel Speed Switch Position Slow (Turtle) Pump Servo Piston Maximum 32—36 sec. at slow (turtle) speed Flow Cycle Time with track raised for three revolution from a running start Pump Servo Piston Maximum 0.3 sec.

approximate per 1/4 turn Flow Cycle Time Change Pump 1 Servo Piston Maximum 6.9 L/min approximate per 1/4 Flow Using a Flow Meter Flow turn Rate Change 1.79 gpm approximate per 1/4 turn Pump 2 Servo Piston Maximum 6.7 L/min approximate per 1/4 Flow Using a Flow Meter Flow turn Rate Change 1.77 gpm approximate per 1/4 turn The purpose of check is to test and adjust the maximum flow rate of pumps using the cycle time for travel as and indicator of pump flow rate. See Pump 1 and 2 Regulator Operation for operation of regulator and servo piston. (Group 9025-05.) 9025 25 48 Maximum flow rate can also be check using a flow meter.

See Pump Flow Test for instruction to connect flow meter to the pumps. (Group 9025-25.) 1. Adjust track sag to specification. See Check and Adjust Track Sag. (Operator’s Manual.) 2. Heat hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) Specification Hydraulic Oil—Temperature........................................................ 45—55°C 110—130°F 3. Raise right track off the ground for pump 1 or left track for pump 2.

Continued on next page LD30992,0000288 –19–22MAR06–1/3 SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Boom Mode Switch Position Off Travel Speed Switch Position Slow (Turtle) Pump Servo Piston Maximum Flow Cycle Time 32—36 sec. at slow (turtle) speed with track raised for three revolution from a running start Pump Servo Piston Maximum Flow Cycle Time Change 0.3 sec.

approximate per 1/4 turn Pump 1 Servo Piston Maximum 6.9 L/min approximate per 1/4 Flow Using a Flow Meter Flow Rate Change turn 1.79 gpm approximate per 1/4 turn Pump 2 Servo Piston Maximum 6.7 L/min approximate per 1/4 Flow Using a Flow Meter Flow Rate Change turn 1.77 gpm approximate per 1/4 turn