John Deere 450DLC — Maximum Flow Test and Adjustment

TM2361 (24JUN08) 9025-25-50 450DLC Excavator Operation and Tests 062608 PN=910 Tests 6. Adjust servo piston maximum flow adjusting screw (7) 7 7 for pump 1 (15) and pump 2 (16) as needed. 3 Loosen nut (8). Turn adjusting screw in to increase the 4 cycle time by decreasing pump flow; turn adjusting screw out to decrease the cycle time by increasing 15 pump flow. Specification 28 5 –UN–23MAR06 Pump Servo Piston Maximum Flow—Cycle Time Change................... 0.3 sec. approximate per 1/4 turn Pump 1 Servo Piston Maximum Flow Using a Flow Meter—Flow Rate Change..............................................

6.9 L/min approximate per 1/4 5 TX1004087 turn 16 27 1.79 gpm approximate per 1/4 turn Pump Servo Piston Minimum and Maximum Adjusting Screws Pump 2 Servo Piston Maximum Flow Using a Flow Meter—Flow Rate Change.............................................. 6.7 L/min approximate per 1/4 9 6 5 7 turn 8 1.77 gpm approximate per 1/4 turn NOTE: The flow rate change for pump 1 is greater because pump 1 turns at 1.03 times engine speed.

–UN–23MAR06 3—Pump 1 (4-Spool) Control Solenoid 4—Pump 2 (5-Spool) Control Solenoid 5—Servo Piston Minimum Flow Adjusting Screw 6—Nut TX1004088 7—Servo Piston Maximum Flow Adjusting Screw 8—Nut 9—Servo Piston Pump Servo Piston Maximum Flow Adjusting Screw 9025 25 50 15—Pump 1 16—Pump 2 27—Pilot Pump 28—Fan Drive Pump LD30992,0000288 –19–22MAR06–3/3