John Deere 450DLC — Travel Motor Leakage Test

TM2361 (24JUN08) 9025-25-64 450DLC Excavator Operation and Tests 062608 PN=924 Tests Travel Motor Leakage Test Monitoring Pump 1 Delivery Pressure 0.00 MPa SPECIFICATIONS Pump 2 Delivery Pressure 0.00MPa Hydraulic Oil Temperature 45—55°C Hydraulic Oil Temperature 0 oC 110—130°F Actual Engine Speed --------min-1 Engine Speed Fast Idle –19–03MAR06 Work Mode Switch Position Dig Mode ON 1 2 3 4 5 Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off 6 7 8 9 0 TX1003295 F1 F2 F3 F4 Precision Mode Switch Position Off Boom Mode Switch Position Off Travel Speed Switch Position Fast (Rabbit) Monitor Travel Motor Leakage 5 L/min typical new 1.32 gpm typical new 10 L/min maximum used 2.64 gpm maximum used SERVICE EQUIPMENT AND TOOLS Vacuum Pump Calibrated Container Test Hose with 3/4-16 M 37° fitting one end JT03221 (3/4-16 M 37°) (Parker No.

03CP-8) Plug 1. Connect one of the following test equipment to perform test: 1. SERVICE ADVISOR application. See SERVICE ADVISOR Connection Procedure for instruction. (Group 9015-20.) Access Travel Motor Leakage Test. Or select the following items from the menu: 9025 25 64 • Hydraulic Oil Temperature • Actual Engine Speed 2. See Personal Digital Assistant (PDA) Connection To Excavator Using Dr. ZX Application for instruction. (Group 9015-20.) Select the following items from the Monitor Display: • Hydraulic Oil Temperature • Actual Engine Speed 3. See Monitor Service Menu Operation for instruction to actuate the service menu on monitor in cab.

(Group 9015-16.) SERVICE ADVISOR is a trademark of Deere & Company Continued on next page TX04577,00000F7 –19–05JUN06–1/3 Engine Speed Work Mode Switch Position Fast Idle Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Precision Mode Switch Position Off Boom Mode Switch Position Off Travel Speed Switch Position Fast (Rabbit) Travel Motor Leakage 5 L/min typical new 1.32 gpm typical new 10 L/min maximum used 2.64 gpm maximum used SERVICE EQUIPMENT AND TOOLS Vacuum Pump Calibrated Container Test Hose with 3/4-16 M 37° fitting one end JT03221 (3/4-16 M 37°) (Parker No. 03CP-8) Plug