TM2361 (24JUN08) 9025-25-78 450DLC Excavator Operation and Tests 062608 PN=938 Tests Fan Drive Pump Servo Piston Maximum Flow Test and Adjustment 3 2 4 5 SPECIFICATIONS 1 Fan Drive Pump Servo Piston 2.8 L/min approximate per 1/4 Maximum Flow Rate Change turn 0.75 gpm approximate per 1/4 turn The purpose of check is to test and adjust the maximum flow rate of the fan drive pump. See Fan Drive Pump –UN–27APR06 Regulator Operation for operation of regulator and servo piston. (Group 9025-05.) 1. Maximum flow rate is checked by using a flow meter. TX1006814 See Fan Drive Pump Flow Test for instruction to connect flow meter to the pump.
(Group 9025-25.) Fan Drive Pump Servo Piston Flow Adjusting Screw 2. Loosen nut (4). Turn adjusting screw (5). Turning 1—Servo Piston Minimum Flow Adjusting Screw screw out decreases pump flow and turning in 2—Nut increases flow. 3—Servo Piston 4—Nut Specification 5—Servo Piston Maximum Flow Adjusting Screw Fan Drive Pump Servo Piston Maximum—Flow Rate Change ................. 2.8 L/min approximate per 1/4 turn 0.75 gpm approximate per 1/4 turn 9025 25 78 TX04577,00000FC –19–27APR06–1/1 SPECIFICATIONS Fan Drive Pump Servo Piston Maximum Flow Rate Change 2.8 L/min approximate per 1/4 turn 0.75 gpm approximate per 1/4