TM2361 (24JUN08) 9025-25-79 450DLC Excavator Operation and Tests 062608 PN=939 Tests Fan Drive Pump Flow Rate Test and Adjustment SPECIFICATIONS Fan Drive Pump Flow Rate Flow 6.5 L/min approximate per 1/4 Rate Change turn 1.7 gpm approximate per 1/4 turn 1 Fan pump flow rate is controlled by a pilot oil signal from 2 the fan pump control solenoid valve to the pilot piston and load on spool in proportion to the current signal to the –UN–26APR06 solenoid. See System Functional Schematic for fan drive pump control solenoid.
(Group 9015-10.) 3 Fan pump flow rate control adjusting screw (3) is used to TX1007050 adjust the response of pilot piston and load spool in proportion to the pilot oil signal by changing the spring (1) force. See Fan Drive Pump Regulator Operation for more Fan Pump Flow Rate Control Adjusting Screw information. (Group 9025-05). 1—Spring 2—Nut 1. Check the maximum and minimum flow rates. See Fan 3—Pump Flow Rate Control Adjusting Screw Drive Pump Flow Test. (Group 9025-25.) 2. Loosen nut (2). Turn adjusting screw (3) in to increase flow rate; turn adjusting screw out to decrease flow rate. Specification Fan Drive Pump Flow Rate— Flow Rate Change......................................
6.5 L/min approximate per 1/4 turn 1.7 gpm approximate per 1/4 turn TX04577,00000FD –19–27APR06–1/1 9025 25 79 Fan Drive Pump Flow Rate Flow Rate Change 6.5 L/min approximate per 1/4 turn 1.7 gpm approximate per 1/4 turn