TM2361 (24JUN08) 9025-25-80 450DLC Excavator Operation and Tests 062608 PN=940 Tests Fan Drive Pump Torque Control Test and Adjustment SPECIFICATIONS 29 Fan Drive Pump Regulator Outer 8.9 L/min approximate per 1/4 32 Spring Flow Rate Change turn 2.4 gpm approximate per 1/4 turn 30 33 31 Fan Drive Pump Regulator Outer 1.9 MPa approximate per 1/4 turn 34 Spring Pressure Change 1900 kPa approximate per 1/4 turn 19 bar approximate per 1/4 turn –UN–28APR06 276 psi approximate per 1/4 turn Fan Drive Pump Regulator Outer 15.1 N•m approximate per 1/4 35 Spring Engine Torque Change turn 11.1 lb-ft approximate per 1/4 TX1007097 turn Fan drive pump torque control is performed by pump Fan Drive Pump Torque Control Adjusting Screw and Plug delivery pressure.
Therefore, the torque constant control is adjusted by changing the spring force of inner spring (31) 29—Fan Drive Pump Regulator and outer spring (30). See Fan Drive Pump Regulator 30—Outer Spring Operation for more information. (Group 9025-05). 31—Inner Spring 32—36 mm Nut 33—24 mm Adjusting Plug 1. Check the fan drive pump maximum and minimum flow 34—13 mm Nut rates. See Fan Drive Pump Flow Test. (Group 35—4 mm Adjusting Screw 9025-25.) 2. Make a mark on the ends adjusting screw (35) and adjusting plug (34) with respect to fan drive pump regulator (29) housing to record the original position. IMPORTANT:
When the 24 mm adjusting plug is adjusted, the inner spring force also 9025 25 80 changes. Therefore, the 4 mm adjusting screw for the inner spring must be turned in the opposite direction to keep the inner spring force unchanged. 3. Loosen 36 mm nut (32). Turn 24 mm adjusting plug (33) for outer spring (30) in to increase flow rate; turn adjusting plug out to decrease flow rate. 4. Loosen 13 mm nut (34).
Continued on next page OUT3035,0000039 –19–27APR06–1/2 SPECIFICATIONS Fan Drive Pump Regulator Outer Spring Flow Rate Change Fan Drive Pump Regulator Outer Spring Pressure Change 8.9 L/min approximate per 1/4 turn 2.4 gpm approximate per 1/4 turn 1.9 MPa approximate per 1/4 turn 1900 kPa approximate per 1/4 turn Fan Drive Pump Regulator Outer Spring Engine Torque Change 19 bar approximate per 1/4 turn 276 psi approximate per 1/4 turn 15.1 N•m approximate per 1/4 turn 11.1 lb-ft approximate per 1/4 turn