Tests Turn 4 mm adjusting screw (35) in the opposite direction 2.24 times the turns of adjusting plug so inner spring (31) force is unchanged. Specification Fan Drive Pump Regulator Outer Spring—Flow Rate Change 8.9 L/min approximate per 1/4 turn ........................ 2.4 gpm approximate per 1/4 turn Pressure Change 1.9 MPa approximate per 1/4 turn .................................. 1900 kPa approximate per 1/4 turn 19 bar approximate per 1/4 turn 276 psi approximate per 1/4 turn Engine Torque Change 15.1 approximate per 1/4 turn ..............................
11.1 lb-ft approximate per 1/4 turn OUT3035,0000039 –19–27APR06–2/2 9025 25 81 TM2361 (24JUN08) 9025-25-81 450DLC Excavator Operation and Tests 062608 PN=941