John Deere 450DLC — Fan Drive Pump Flow Test

TM2361 (24JUN08) 9025-25-82 450DLC Excavator Operation and Tests 062608 PN=942 Tests Fan Drive Pump Flow Test SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position P Mode Auto Idle Switch Position Off Fan Drive Pump Flow Rate—New 61.3 L/min at 7.9 MPa and 1750 rpm 61.3 L/min at 7930 kPa and 1750 rpm 61.3 L/min at 79.3 bar and 1750 rpm 16.2 gpm at 1150 psi and 1750 rpm Fan Drive Pump Flow Rate—New 57.5 L/min at 23.3 MPa and 1750 rpm 57.5 L/min at 23 305 kPa and 1750 rpm 57.5 L/min at 233.1 bar and 1750 rpm 15.2 gpm at 3380 psi and 1750 rpm Fan Drive Pump Flow Rate—New 82.5 L/min at 26.3 MPa and 1750 rpm 82.5 L/min at 26 270 kPa and 1750 rpm 82.5 L/min at 262.7 bar and 1750 rpm 13.3 gpm at 3810 psi and 1750 rpm Fan Drive Pump Flow Rate— 50.3 L/min at 7.9 MPa and 1750 Minimum Allowable rpm 50.3 L/min at 7930 kPa and 1750 rpm 50.3 L/min at 79.3 bar and 1750 rpm 13.8 gpm at 1150 psi and 1750 rpm Continued on next page OUT3035,000000D –19–05JUN06–1/6 9025 25 82 SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position P Mode Auto Idle Switch Position Off Fan Drive Pump Flow Rate—New 61.3 L/min at 7.9 MPa and 1750 rpm 61.3 L/min at 7930 kPa and 1750 rpm 61.3 L/min at 79.3 bar and 1750 rpm 16.2 gpm at 1150 psi and 1750 rpm Fan Drive Pump Flow Rate—New 57.5 L/min at 23.3 MPa and 1750 rpm 57.5 L/min at 23 305 kPa and 1750 rpm 57.5 L/min at 233.1 bar and 1750 rpm 15.2 gpm at 3380 psi and 1750 rpm Fan Drive Pump Flow Rate—New 82.5 L/min at 26.3 MPa and 1750 rpm 82.5 L/min at 26 270 kPa and 1750 rpm 82.5 L/min at 262.7 bar and 1750 rpm 13.3 gpm at 3810 psi and 1750 rpm Fan Drive Pump Flow Rate— 50.3 L/min at 7.9 MPa and 1750 Minimum Allowable rpm 50.3 L/min at 7930 kPa and 1750 rpm 50.3 L/min at 79.3 bar and 1750 rpm 13.8 gpm at 1150 psi and 1750 rpm