Komatsu — AFTER RUNNING OUT OF FUEL

. OPERATION TROUBLESHOOTING TROUBLESHOOTING AFTER RUNNING OUT OF FUEL the engine runs out of fuel, add fuel to the fuel tank, then bleed the air from the fuel system before starting the engine. PROCEDURE FOR BLEEDING AIR CAUTION (2). 3 - 125 I f t The fuel injection pu mp and nozzle of this e ngine consist of more p recise parts than the conventi onal ones. If foreign matter enters them, it can c ause a trouble. Accord ingly, if d ust s ticks to t he fue l system, wash it off with Be careful when ope ning the air bleed plug in the fue l filte r head. T he internal pressure may caus 1. 2. Fill the fuel tank Loosen air bleed Do not loosen th is loosened, air i with fuel.

ing plug (1) at the fuel main filter head. e plug at the filter head of the fuel prefilter. s not bled. 3. Loosen wing nu Pump lever (4) until bubbles sto t (3) holding lever (4) of priming pump up and down to carry out priming. Conti p coming out with the fuel from the hole for 4. bleed plug (1). Tighten air bleed ing plug (1) and then tighten wing bolt (3 ) securely to lock lever (4). que for air bleeding plug 0.8 to 1kgm} que for wing screw {0.7 to 1.3kgm} he starting switch to the START position s, do not keep the starting motor rota more than 20 seconds.

s not start, wait for at least 2 minutes bef priming pump (2 Tightening tor 7.8 to 9.8Nm{ Tightening tor 6.9 to 12.7Nm priming pump (2 ) securely to lock lev Tightening tor que for air bleeding p 5. Turn the key in t he starting switch to start the engine. When doing thi continuously for more than 20 second If the engine doe s not start, wait for a t least 2 trying again. Ca rry out this operation a maximum of 4 tim 6. If the engine doe s not start, repeat the procedure fr om Ste