Komatsu — DETAILS OF DATA STORED IN MEMORY OF PAYLOAD METER

. ATTACHMENTS, OPTIONS HANDLING PAYLOAD METER HM *1: Every time the engine is switched ON, the engine operation No. advances by one, and is recorded. The engine operation No. in the cycle data and the engine operation No. in the abnormality/warningdata, which are recorded from the time the engine is switched ON to the time it is switched OFF, are all recorded as an equal value. As a result, when using our personal computer later to compile the data, it is possible to determine what time during the engine operation the cycle data or system abnormality refers to.

6 - 16 ABNORMALITY, WARNING DATA When a problem or warning occurs or i s restored in the payload meter system, these data are recorded in RAM. The maximum limit for problem/warning data is 230 sets of occur/restore. Item Unit Range Error code Engine operation No. when occurred Number of times of occurrence since engine was switched ON Year (last 2 digits) Month Day Time Hour Time Min - Integer Times Year Month Day Hour Minute 0 - 65535 1 - 255 0 - 99 1 - 12 1 - 31 0 - 23 0 - 59 See section on abnormality/warning display (*1) Shows when abnormality restored Engine operation No.

when restored Year (last 2 digits) Month Day Time Hour Time Min Integer Year Month Day Hour Minute 0 - 65535 0 - 99 1 - 12 1 - 31 0 - 23 0 - 59 Shows when abnormality restored