Komatsu — WHEN REQUIRED

. MAINTENANCE SERVICE PROCEDURE CLEANING OR REPLACING OUTER ELEMENT NOTICE Before and after cleaning the element, do not leave or keep it in direct sunlight. 1. Remove 6 holders (2), then remove cover (3) and take out outer element (4). 4 - 23 NOTICE Never r emove t he inner element (5). It will allow dirt to en ter and cause failure of the en gine. rewdriver or other tool. Do not use a sc rewdriver or othe 2. Hold the out er element (4), move it carefully up a nd down and to th e left an d right, and rota te the element to the left and right while pulling it out. ing the outer element, cover the air connector 3.

After remov insid e the ai r cleaner body w ith a clean cloth or ta pe to prevent dirt o r dust f rom entering. 4. Use a brush or cloth to remo ve all the dirt stuck to c over (3) and the i nside of air cleaner bod y (6). 5. Direc t dry c ompressed air (Max. 0.69 MPa (7 kg/cm2, 99.4 PSI)) from th e inside of the o uter element along its folds. Then direc t the co mpressed air fr om the outside along t he folds, and agai n from t he inside.