TROUBLESHOOTING BEFORE CARRYING OUT TROUBLESHOOTING WHEN CODE IS DISPLAYED Troubles which occur when controller power supply of governor and pump controller is defective a The controller power supply (FB1-1) of the governor and pump controller drives the controller system. a Accordingly, if the controller power supply is turned off, the controller cannot control the governor motor and battery relay and the following troubles occur. 1) The engine can be started but cannot be stopped. 2) The engine speed cannot be controlled with the fuel control dial.
a If the above problems occur, check the related fuse (FB1-1) and "green LED" of the governor and pump controller to see if the power is supplied normally. Lighting: The controller power is supplied (There is not an error and the power supply is normal). Flashing: The controller power is supplied (There is an error). Put out: The controller power is not supplied. a Green LED of governor and pump controller (GREEN) PC130-7 20-305 (1)