TROUBLESHOOTING [104] Error code [104] (Clogging of air cleaner) Circuit diagram related to air cleaner clogging switch 20-310 PC130-7 (1) User code Error code Trouble Clogging of air cleaner(Monitor panel system) – 104 Contents of trouble • The signal circuit of the air cleaner clogging switch is opened (disconnected from the chassis ground) while the engine is running. Action of monitor panel • None in particular. Problem that appears on machine • If the machine is operated as it is, the engine may be damaged. Related information • If the air cleaner clogging monitor of the monitor panel flashes while the engine is running, this error code is recorded.
• The input state (ON/OFF) from the air cleaner clogging switch can be checked with the monitoring func- tion. (Code: 046, Right of upper line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Clogging of air cleaner 1 (When system is normal) Check the air cleaner. If it is clogged, clean or replace it. Defective air cleaner clog- 2 ging switch (Internal dis- connection) aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting.
A31 (male) Air cleaner Resistance Between (1) and (2) When normal When clogged Max.1 z Min.1 Mz Disconnection in wiring harness (Disconnection in 3 wiring harness or defective A contact in connector) c aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between P02 (female) (5) and 31 (female) (1) Resistance Max.1 z Wiring harness between P11 (female) (2) and hassis ground (A15) Resistance Max.1 z 4 Defective monitor panel aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. P02 Air cleaner Voltage Between (5) and chassis ground When normal When clogged Max. 1 V 20 – 30 V