Komatsu — TROUBLESHOOTING

TROUBLESHOOTING [112] Error code [112] (Short circuit in wiper motor drive forward system) 20-312 PC130-7 (1) User code Error code Trouble Short circuit in wiper motor drive forward system (Monitor panel system) – 112 Contents of trouble • When the signal is output to the wiper motor drive forward circuit, an abnormal current flows. Action of monitor panel • Turns the output to the wiper motor drive forward circuit OFF. Problem that appears on machine • Windshield wiper stops.

Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective wiper motor (Internal short circuit or grounding fault) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. W04 (male) Continuity/Resistance Between (3) and (1) There is continuity Between (3) and chassis ground Min. 1 Mz 2 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between P01 (female) (9) – W03 (female) (3) wiring harness and chassis ground Resistance Min.

1 Mz 3 Defective monitor panel aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. P01 Wiper switch Resistance Between (9) and chassis ground OFF Max. 3 V ON Max. 3 V 20 – 30 V (Constant period)