TROUBLESHOOTING [222] Error code [222] (Short circuit in LS-EPC solenoid) Circuit diagram related to LS-EPC solenoid 20-338 PC130-7 (1) User code Error code Trouble ( Short circuit in LS-EPC solenoid Governor and pump controller system) – 222 Contents of trouble • An abnormal current flows in the LS-EPC solenoid circuit Action of controller • Reduces the output to the LS-EPC solenoid circuit 0. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem tha appears on machine t • The travel speed is fast at Lo. Amount of flow is large at model B.
(The set pressure of the LS valve cannot be controlled) Related information • The output state (current) to the LS-EPC solenoid can be checked with the monitoring function. (Code: 015, by 10 mA) Possible cause and standard value in norma state Cause Defective LS-EPC sole- 1 noid (Internal short circuit) s Short circuit with chassis ground in wiring harness l 2 (Contact with ground cir- cuit) Defective governor and 3 pump controller Standard value in normal state/Remarks on troubleshooting aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. V22 (male) Resistance Between (1) and (2) 7 – 14 z Between (1) and chassis ground Min.
1 Mz aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C03 (female) (6) – V22 (female) (1) wiring harness and chassis ground Resistance Min . 1 Mz aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C03 Resistance Between (6) and (3), (13), (23) 7 – 14 z Between (6) and chassis ground Min. 1 Mz