TROUBLESHOOTING [223] Error code [223] (Disconnection in LS-EPC solenoid) Circuit diagram related to LS-EPC solenoid PC130-7 20-339 (1) User code Error code Trouble ( Disconnection in LS-EPC solenoid Governor and pump controller system) – 223 Contents of trouble • No current flows in the LS-EPC solenoid circuit Action of controller • None in particular (Since no current flows, the solenoid does not operate). • If the cause of the failure disappears, the system resets itself. Problem tha appears on machine t • The travel speed is fast at Lo. Amount of flow is large at model B.
(The set pressure of the LS valve cannot be controlled) Related information • The output state (current) to the LS-EPC solenoid can be checked with the monitoring function. (Code: 015, by 10 mA) Possible cause and standard value in norma state Cause Defective LS-EPC sole- 1 noid (Internal short circuit) Disconnection in wiring harness (Disconnection in s 2 wiring harness or defective contact in connector) l ( Short circuit with power 3 source in wiring harness (Contact with 24-V circuit) Defective governor and 4 pump controller Standard value in normal state/Remarks on troubleshooting aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
V22 (male) Resistance Between (1) and (2) 7 – 14 z aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between C03 (female) (6) and V22 (female) (1) Resistance Ma x. 1 z Wiring harness between C03 (female) (3), (13), 23), and V22 (female) (2) Resistance Ma x. 1 z aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C03 (female) (6) – V22 (female) (1) wiring harness and chassis ground Voltage M ax. 1 V aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. C03 Resistance Between (6) and (3), (13), (23) 7 – 14 z