TROUBLESHOOTING [224] Error code [224] (Abnormality in pump pressure sensor) 20-340 PC130-7 (1) User code Error code Trouble Abnormality in pump pressure sensor (Governor and pump controller system) – 224 Contents of trouble • The signal voltage from the pump pressure sensor is below 0.3 V or above 4.72 V. Action of controller • Sets the pump pressure to 0 MPa {0 kg/cm2} for control. • If the cause of the failure disappears, the system resets itself. Problem that appears on machine • The travel speed does not change automatically (The travel load pressure cannot be sensed).
• Cut-off function dose not work (The work equipment pressure can not be detected.) Related information • If the 5-V circuit (B) and ground circuit (A) of the pressure sensor are connected inversely, the pressure sensor will be broken. Accordingly, take extreme care when checking. • The input state (ON/OFF) from the pump pressure sensor can be checked with the monitoring function. (Code: 011, 012, by 1 kg/cm2) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor power supply If error code [226] is displayed, carry out troubleshooting for it first.
2 Defective pump pressure sensor (Internal defect) aPrepare with starting switch OFF, then hold starting switch ON or start engine and carry out troubleshooting. A51 Voltage Between (B) and (A) Power supply 4.5 – 5.5 V Between (C) and (A) Signal 0.5 – 4.5 V The pressure sensor voltage is measured with the wiring harness con- nected. Accordingly, if the voltage is abnormal, check the wiring har- ness and controller, too, for another cause of the trouble, and then judge. 3 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
Wiring harness between C01 (female) (22) and J07 and A51 (female) (B) Resistance Max. 1 z Wiring harness between C01 (female) (10) and A51 (female) (A) Resistance Max. 1 z Wiring harness between C01 (female) (8) and A51 (female) (C) Resistance Max. 1 z 4 Short circuit with chassis ground in wiring harness (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between C01 (female) (8) – A51 (female) (C) wiring harness and chassis ground Resistance Min.
1 Mz 5 Short circuit with power source in wiring harness (Contact with 24-V circuit) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Between C01 (female) (22) – J07 – A51 (female) (B) wiring harness and chassis ground Voltage Max. 1 V Between C01 (female) (8) – A51 (female) (C) wiring harness and chassis ground Voltage Max. 1 V 6 Defective governor and pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C01 Voltage Between (22) and (10) Power supply 4.5 – 5.5 V Between (8) and (10) Signal 0.5 – 4.5 V