Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-9 E-9 One-touch power maximizing system does not operate Circuit diagram related to one-touch power maximizing switch 20-420 PC130-7 (1) Trouble • One-touch power maximizing system does not operate. Related information • The input state (ON/OFF) from the one-touch power maximizing switch (left knob switch) can be checked with the monitoring function. (Code: 022, Center of upper line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 9 If the fuse is broken, the circuit probably has a grounding fault, etc.

(See cause 4.) Defective one-touch power 2 maximizing switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. M23 (male) One-touch power maximizing switch Resistance Between (1) and (4) Released Min. 1 Mz Pressed Max. 1 z Disconnection in wiring harness 3 (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between FB1-9 outlet and M23 (female) (1) Resistan ce Max. 1 z Wiring harness between M23 (female) (4) and C01 (female) (1) Resistan ce Max.

1 z Short circuit with chassis ground in wiring harness 4 (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between FB1-9 outlet – M23 (female) (1) wiring harness and chassis ground Resistan ce Min. 1 Mz Between M23 (female) (4) – C01 (female) (1) wiring harness and chassis ground Resistan ce Min. 1 Mz Defective governor and 5 pump controller aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. C01 One-touch power maximizing switch Voltage Between (11) and chassis ground Released Max. 1 V Pressed 20 – 30 V