Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-14 E-14 While engine is running, caution items flash 20-424 PC130-7 (1) Trouble (1) Battery charge level monitor flashes. Related information • While the engine is running, if the battery charge level monitor detects lowering of the charge voltage, it flashes. • The generation state (Voltage) of the alternator and the input state (ON/OFF) of the generation signal can be checked with the monitoring function. (Code:

043, by 10 mV, left of lower line) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective alternator (Defective charge) aPrepare with starting switch OFF, then start engine and carry out trou- bleshooting. E08 (female) Engine speed Voltage Between (1) and chassis ground Above medium (half) speed 20 – 30 V 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between P02 (female) (11) and J02 and E08 (male) (1) Resistance Max.

1 z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between P02 (female) (11) – J02 – E08 (male) (1) or A27 (female) (2) or D01 – J01 – D01 (female) (1) or H15 (female) (2) or A21 (BR) wiring harness and chassis ground Resistance Min. 1 Mz 4 Defective monitor panel aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. E08 (female) Engine speed Voltage Between (1) and chassis ground Above medium (half) speed 20 – 30 V