TROUBLESHOOTING E-32 PC130-7 20-467 (1) Self-diagnosis notice Trouble Short circuit in daylight sensor E18 Contents of trouble • Short circuit in the daylight sensor is detected. Action of controller • Assumes that the daylight sensor is not installed for control. • If the following condition is satisfied, the trouble is reset. + + + Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective daylight sensor (Internal short circuit) The daylight sensor may be defective. Check it directly.
2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between M30 (female) (16) and P15 (female) (2) Resistance Max. 1 z Wiring harness between M30 (female) (3) and P15 (female) (1) Resistance Max. 1 z 3 Defective air conditioner system If neither of causes 1 and 2 is the cause of the trouble, the air condi- tioner system may be defective. See Shop Manual for Chassis Compo- nents, Troubleshooting for air conditioner.
Self-diagnosis notice Trouble Abnormality in air outlet damper E43 Contents of trouble • Abnormality in the air outlet servomotor system is detected. Action of controller • Stops the servomotor. • If the following condition is satisfied, the trouble is reset. + + + Related information aDo not connect the power cables to the motor terminals directly to drive the motor. Doing so can dam- age the motor output shaft and break the motor coils. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective air outlet servomotor (Internal defect) The air outlet servomotor may be defective. Check it directly.
2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch. Wiring harness between Mv1 (female) (1) and M30 (female) (3) Resistance Max. 1 z Wiring harness between Mv1 (female) (3) and M29 (female) (11) Resistance Max. 1 z Wiring harness between Mv1 (female) (5) and M30 (female) (9) Resistance Max. 1 z Wiring harness between Mv1 (female) (6) and M29 (female) (8) Resistance Max. 1 z Wiring harness between Mv1 (female) (7) and M29 (female) (9) Resistance Max.
1 z 3 Defective air conditioner system If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system may be defective. See Shop Manual for Chassis Components, Troubleshooting for air conditioner.