Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-32 20-468 PC130-7 (1) Self-diagnosis notice Trouble Abnormality in air mix damper E44 Contents of trouble • Abnormality in the air mix servomotor system is detected. Action of controller • Stops the air mix servomotor. • If the following condition is satisfied, the trouble is reset. + + + Related information aDo not connect the power cables to the motor terminals directly to drive the motor. Doing so can dam- age the motor output shaft and break the motor coils. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective air mix servomotor (Internal defect) The air mix servomotor may be defective.

Check it directly. 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch. Wiring harness between MAM (female) (1) and M29 (female) (11) Resistance Max. 1 z Wiring harness between MAM (female) (3) and M30 (female) (3) Resistance Max. 1 z Wiring harness between MAM (female) (5) and M30 (female) (2) Resistance Max. 1 z Wiring harness between MAM (female) (6) and M29 (female) (4) Resistance Max. 1 z Wiring harness between MAM (female) (7) and M29 (female) (5) Resistance Max.

1 z 3 Defective air conditioner system If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system may be defective. See Shop Manual for Chassis Components, Troubleshooting for air conditioner.