Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-32 PC130-7 20-469 (1) Self-diagnosis notice Trouble Abnormality in air mix damper E45 Contents of trouble • Abnormality in the internal and external air servomotor is detected. Action of controller • Stops the internal and external air servomotor. • If the following condition is satisfied, the trouble is reset. + + + Related information aDo not connect the power cables to the motor terminals directly to drive the motor. Doing so can dam- age the motor output shaft and break the motor coils.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective internal and external air servomotor (Internal defect) The internal and external air servomotor may be defective. Check it directly. 2 Defective fuse (in unit) If the fuse (in the unit) is broken, the circuit probably has a grounding fault, etc. Check the related circuits. 3 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch. Wiring harness between MRF (female) (1) and M29 (female) (6) Resistance Max.

1 z Wiring harness between MRF (female) (3) and M29 (female) (7) Resistance Max. 1 z Wiring harness between MRF (female) (7) and fuse in unit and M33 (male) (3) Resistance Max. 1 z 4 Defective air conditioner system If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system may be defective. See Shop Manual for Chassis Components, Troubleshooting for air conditioner.