TROUBLESHOOTING E-32 Troubleshooting by trouble PC130-7 20-471 (1) Trouble (1) Air conditioner does not operate at all. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 11 If the fuse is broken, the circuit probably has a grounding fault, etc. (See cause 3.) 2 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between FB1-11 outlet and M33 (female) (3) Resistance Max.
1 z Wiring harness between M27 (female) (14) and M30 (female) (6) Resistance Max. 1 z Wiring harness between M33 (female) (2) and chassis ground (A13) Resistance Max. 1 z Wiring harness between M29 (female) (12) and chassis ground (A13) Resistance Max. 1 z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Between FB1-11 outlet – M33 (female) (3) wir- ing harness and chassis ground Resistance Min. 1 Mz Between M27 (female) (14) – M30 (female) (6) wiring harness and chassis ground Resistance Min.
1 Mz 4 Defective air conditioner unit aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. M33 Voltage Between (2) and (3) 20 – 30 V If the above voltage is normal and the air conditioner unit does not oper- ate, the air conditioner unit is defective. 5 Defective control panel aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. M30, M29 Voltage Between M30 (6) and M29 (12) 20 – 30 V If the above voltage is normal and the control panel does not operate, the control panel is defective.