Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-32 20-472 PC130-7 (1) Trouble (2) Air does not come out (Air flow is insufficient). Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse (in unit) If the fuse (in the unit) is broken, the circuit probably has a grounding fault, etc. Check the related circuits. 2 Defective blower relay (coil side) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

R30 (male) Resistance Between (1) and (3) 140 – 340 z 3 Defective blower relay (contact side) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. R30 Fan switch Voltage Between (4) and chassis ground ON (Operation) position 20 – 30 V 4 Defective power transistor (Internal defect) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. Fan switch If air flow changes as fan switch is operated, power transistor is nor- mal. Operate between Low and Medium and High. 5 Defective blower motor (Internal defect) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting.

MB (female) Fan switch Voltage Between (1) and (2) ON (Operation) position 20 – 30 V If the above voltage is normal and the blower motor does not rotate, the blower motor is defective. 6 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between FB1-11 outlet and fuse in unit and R30 (female) (3) or R31 (female) (1) or M30 (female) (6) Resistance Max. 1 z Wiring harness between M29 (female) (3) and R30 (female) (1) Resistance Max. 1 z Wiring harness between M29 (female) (12) and chassis ground (A13) Resistance Max.

1 z Wiring harness between MB (female) (1) and R30 (female) (4) Resistance Max. 1 z Wiring harness between MB (female) (2) and PTR (female) (3) Resistance Max. 1 z Wiring harness between PTR (female) (1) and chassis ground (A13) Resistance Max. 1 z Wiring harness between PTR (female) (2) and M30 (female) (7) Resistance Max. 1 z Wiring harness between PTR (female) (4) and M30 (female) (8) Resistance Max. 1 z 7 Defective air conditioner system If none of causes 1 – 6 is the cause of the trouble, the air conditioner system may be defective. See Shop Manual for Chassis Components, Troubleshooting for air conditioner.