TROUBLESHOOTING E-32 PC130-7 20-473 (1) Trouble (3) Air is not cooled (Cooling performance is insufficient). Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse (in unit) If the fuse (in the unit) is broken, the circuit probably has a grounding fault, etc. Check the related circuits. 2 Defective compressor relay (coil side) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.
R31 (male) Resistance Between (1) and (2) 140 – 340 z 3 Defective compressor relay (contact side) aPrepare with starting switch OFF, then turn starting switch ON and car- ry out troubleshooting. (Set temperature: Max. cooling) R31 Fan switch Voltage Between (4) and chassis ground ON (Operation) position 20 – 30 V 4 Defective thermostat (Internal defect) The thermostat may be defective. Check it directly. 5 Defective high/low pressure switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. P17 (male) Resistance Between (1) and (2) Max.
1 z 6 Defective compressor (Internal defect) The compressor clutch may be defective. Check it directly. 7 Defective compressor (Internal defect) The compressor may be defective. Check it directly. 8 Disconnection in wiring harness (Disconnection in wiring harness or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. Wiring harness between M30 (female) (4) and P17 (female) (1) Resistance Max. 1 z Wiring harness between P17 (female) (2) and J04 and chassis ground (A12) Resistance Max.
1 z Wiring harness between FB1-11 outlet and R31 (female) (2) or fuse in unit and R31 (female) (1) or M30 (female) (6) Resistance Max. 1 z Wiring harness between ST1 (female) (1) and R31 (female) (3) Resistance Max. 1 z Wiring harness between M29 (female) (2) and ST1 (female) (2) Resistance Max. 1 z Wiring harness between M29 (female) (12) and chassis ground (A13) Resistance Max. 1 z Wiring harness between R31 (female) (4) and E06 (female) (1) Resistance Max. 1 z 9 Defective air conditioner system If none of causes 1 – 8 is the cause of the trouble, the air conditioner system may be defective. See Shop Manual for Chassis Components, Troubleshooting for air conditioner.