TROUBLESHOOTING H-1 H-1 Speed or power of whole work equipment, swing, and travel is low 20-506 PC130-7 (1) Trouble • Speed or power of whole work equipment, swing, and travel is low. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective unload valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.
Control levers Unload pressure All levers in neutral 2.4 – 3.4 MPa {25 – 35 kg/cm2} 2 Defective adjustment or malfunction of main relief valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting Control levers Main relief pressure Arm-IN circuit relieved 33.6 – 37.0 MPa {343 – 378 kg/cm2} If the oil pressure does not become normal after adjustment, the main relief valve may have a malfunction or a defect in it. Check the main relief valve directly.
3 Defective self-reducing pressure valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting Control levers Control circuit basic pressure All levers in neutral 2.84 – 3.43 MPa {29 – 35 kg/cm2} 4 Defective adjustment or malfunction of PC valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting Measured pump discharge pressure Measurement conditions Oil pressure ratio Pump discharge pressure Swing lock switch: LOCK Arm-IN circuit relieved 1 PC valve output pressure 0.6 (3/5) If the oil pressure does not become normal after adjustment, the PC valve may have a malfunction or a defect in it.
Check the PC valve directly. 5 Defective adjustment or malfunction of LS valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting Measured pump discharge pressure Oil pressure ratio All levers in neutral Either track shoe driven idle (Full stroke) Pump discharge pressure Almost same pressure 1 LS valve output pressure 0.6 (3/5) If the oil pressure does not become normal after adjustment, the LS valve may have a malfunction or a defect in it. Check the LS valve directly. 6 Malfunction of servo piston The servo piston may have a malfunction. Check it directly.
7 Defective piston pump If none of above causes is the cause of the trouble, the cause may be lowering performance, malfunction, or internal defect of the piston pump.