Komatsu — TROUBLESHOOTING

TROUBLESHOOTING H-12, H-13 H-12 Time lag of work equipment is large H-13 One-touch power maximizing function does not work PC130-7 20-515 (1) Trouble • Time lag of work equipment is large. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of control valve (regeneration valve) [Only boom] The regeneration valve of the control valve may have a malfunction. Check it directly. 2 Malfunction of control valve (Suction valve) The suction valve of the control valve may have a malfunction. Check it directly.

Trouble • One-touch power maximizing function does not work. Related information • Carry out installation in the reverse order to removal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of 2-stage relief solenoid valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Swing lock switch Solenoid valve output pressure OFF 0 MPa {0 kg/cm2} LOCK 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of main relief valve The main relief valve of the control valve may have a malfunction. Check it directly.