TROUBLESHOOTING H-17 H-17 Machine deviates during travel PC130-7 20-517 (1) Trouble • Machine deviates during travel. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of self-reduc- ing pressure valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Control levers Control circuit basic pressure All levers in neutral 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of travel PPC valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.
Travel lever PPC valve output pressure FORWARD or REVERSE position 2.84 – 3.43 MPa {29 – 35 kg/cm2} Difference between right and left of above Max. 0.4 MPa {Max. 4 kg/cm2} 3 Malfunction of travel junc- tion valve The travel junction valve of the control valve may have a malfunction. Check it directly. 4 Malfunction of travel control valve (spool) The spool of the travel control valve may have a malfunction. Check it directly. 5 Defective seal of center swivel joint The seal of the center swivel joint may be defective. Check it directly. 6 Defective travel motor aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.
Travel lever Relieved in TRAVEL position Leakage from travel motor Max. 10 l/min 7 Defective final drive The final drive may have a defect in it. Check it directly. (It may be checked by abnormal sound, abnormal heating, metal chips in drain oil, etc.)