Komatsu — TROUBLESHOOTING

TROUBLESHOOTING H-22 H-22 Upper structure does not swing PC130-7 20-521 (1) Trouble (1) Upper structure does not swing in either direction. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing hold- ing brake solenoid valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.

Right work equipment control lever Solenoid valve output pressure Neutral position 0 MPa {0 kg/cm2} SWING position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of swing motor (parking brake) The parking brake of the swing motor may have a malfunction. Check it directly. 3 Malfunction of swing motor (safety valve) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Swing lock switch Left work equipment control lever Swing relief pressure LOCK Relieved in SWING position 28.9 – 32.9 MPa {295 – 335 kg/cm2} 4 Defective swing motor (motor unit) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.

Swing lock switch Left work equipment control lever Swing relief pressure LOCK Relieved in SWING position Max. 6 l/min 5 Defective swing machinery The swing machinery may have a defect in it. Check it directly. (It may be checked by abnormal sound, abnormal heating, metal chips in drain oil, etc.) Trouble (2) Upper structure swings only in 1 direction. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing PPC valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.

Right work equipment control lever PPC valve output pressure Neutral position 0 MPa {0 kg/cm2} SWING position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of swing con- trol valve (spool) The spool of the swing control valve may have a malfunction. Check it directly. 3 Defective seal of swing motor (suction valve) The seal of the suction valve of the swing motor may be defective. Check it directly.