TROUBLESHOOTING H-23 H-23 Swing acceleration or swing speed is low 20-522 PC130-7 (1) Trouble (1) Swing acceleration or swing speed is low in both directions. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing con- trol valve (pressure com- pensation valve) The pressure compensation valve of the swing control valve may have a malfunction. Check it directly. 2 Malfunction of swing bleed valve The swing bleed valve of the control valve may have a malfunction. Check it directly.
3 Malfunction of swing motor (parking brake) The parking brake of the swing motor may have a malfunction. Check it directly. 4 Malfunction of swing motor (safety valve) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Swing lock switch Left work equipment control lever Swing relief pressure LOCK position Relieved in SWING position 28.9 – 32.9 MPa {295 – 335 kg/cm2} 5 Defective swing motor (motor unit) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Swing lock switch Left work equipment control lever Leakage from swing motor LOCK position Relieved in SWING position Max.
6 l/min 6 Defective swing machinery The swing machinery may have a defect in it. Check it directly. (It may be checked by abnormal sound, abnormal heating, metal chips in drain oil, etc.) Trouble (2) Swing acceleration or swing speed is low in only 1 direction. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing PPC valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.
Right work equipment control lever PPC valve output pressure In NEUTRAL position 0 MPa {0 kg/cm2} In SWING position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Clogging of swing PPC slow return valve The swing PPC slow return valve may be clogged. Check it directly. 3 Malfunction of swing con- trol valve (spool) The spool of the swing control valve may have a malfunction. Check it directly (including the stroke limiting mechanism). 4 Defective seal of swing motor (suction valve) The seal of the suction valve of the swing motor may be defective. Check it directly.