Komatsu — TROUBLESHOOTING

TROUBLESHOOTING H-24 H-24 Upper structure overruns remarkably when it stops swinging PC130-7 20-523 (1) Trouble (1) Upper structure overruns remarkably when it stops swinging in both directions. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing motor (safety valve) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.

Swing lock switch Left work equipment control lever Swing relief pressure LOCK position Relieved in SWING position 28.9 – 32.9 MPa {295 – 335 kg/cm2} 2 Defective swing motor (motor unit) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Swing lock switch Left work equipment control lever Leakage from swing motor LOCK position Relieved in SWING position Max. 6 l/min Trouble (2) Upper structure overruns remarkably when it stops swinging in only 1 direction. Related information • Carry out the troubleshooting in working mode A.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing PPC valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Right work equipment control lever PPC valve output pressure In NEUTRAL position 0 MPa {0 kg/cm2} In SWING position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Clogging of swing PPC slow return valve The swing PPC slow return valve may be clogged. Check it directly. 3 Malfunction of swing con- trol valve (spool) The spool of the swing control valve may have a malfunction. Check it directly.

4 Defective seal of swing motor (suction valve) The seal of the suction valve of the swing motor may be defective. Check it directly.