TROUBLESHOOTING H-25, H-26 H-25 Large shock is made when upper structure stops swinging H-26 Large sound is made when upper structure stops swinging 20-524 PC130-7 (1) Trouble • Large shock is made when upper structure stops swinging. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing PPC valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.
Right work equipment control lever PPC valve output pressure In NEUTRAL position 0 MPa {0 kg/cm2} In SWING position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of swing PPC slow return valve The swing PPC slow return valve may have a malfunction. Check it directly. 3 Malfunction of swing motor (shockless valve) The shockless valve of the swing motor may have a malfunction. Check it directly. Trouble • Large sound is made when upper structure stops swinging. Related information • Carry out the troubleshooting in working mode A.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of back-pres- sure check valve The back-pressure check valve may have a malfunction. Check it directly. 2 Malfunction of swing motor (safety valve) The swing motor (safety valves) may have a malfunction. Check it directly. (It may be checked by exchanging both valves and seeing the change of phenomenon.) 3 Malfunction of swing motor (suction valve) The swing motor (suction valves) may have a malfunction. Check it directly.
(It may be checked by exchanging both valves and seeing the change of phenomenon.) 4 Defective swing machinery The swing machinery may have a defect in it. Check it directly. (It may be checked by abnormal sound, abnormal heating, metal chips in drain oil, etc.)