Komatsu — TROUBLESHOOTING

TROUBLESHOOTING H-27 H-27 Hydraulic drift of swing is large PC130-7 20-525 (1) Trouble (1) When swing holding brake is applied Related information • When the swing lock switch is in the LOCK position or when the swing holding brake release switch is in the normal position, the swing holding brake operates and the upper structure is fixed with the disc brake. • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing hold- ing brake solenoid valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.

Right work equipment control lever Solenoid valve output pressure In NEUTRAL position 0 MPa {0 kg/cm2} In SWING position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction or internal defect of swing motor (parking brake) The parking brake of the swing motor may have a malfunction or a defect in it. Check it directly. Trouble (2) When swing holding brake is released Related information • When the swing holding brake release switch is in the RELEASE position, the swing brake is released and the upper structure is secured by only hydraulic pressure. • Carry out the troubleshooting in working mode A.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective seal of swing control valve (spool) The seal of the spool of the swing control valve may be defective. Check it directly. 2 Defective seal of swing control valve (safety valve) The seal of the safety valve of the swing control valve may be defective. Check it directly. 3 Defective seal of swing control valve (suction valve) The seal of the suction valve of the swing control valve may be defec- tive. Check it directly. 4 Defective seal of swing control valve (shockless valve) The seal of the shockless valve of the swing control valve may be defec- tive.

Check it directly.