TESTING AND ADJUSTING TESTING AND ADJUSTING OIL PRESSURE IN PUMP LS CONTROL CIRCUIT TESTING AND ADJUSTING OIL PRESSURE IN PUMP LS CONTROL CIRCUIT (2): LS valve output pressure pickup plug (at top of hydraulic pump) a Testing and adjusting instruments for oil pressure in pump LS control circuit MEASURING 1. Measuring LS valve output pressure (servo piston inlet pressure) a Before measuring the LS valve output pres- sure (servo piston inlet pressure), check that the oil pressure in the work equipment, swing, and travel circuits and the basic pres- sure in the control circuit are normal.
a Measure the LS valve output pressure (servo piston inlet pressure) and pump discharge pressure simultaneously and compare them. 3) Install nipple L2 and connect it to oil pressure gauge [1] of hydraulic tester L1 . a Use the oil pressure gauge of 58.8 MPa {600 kg/cm 2 }. The drawing shows the pump discharge pressure side. k Lower the work equipment to the ground and stop the engine. Operate the control levers several times to release the residual pressure in the piping, and then loosen the oil filler cap of the hydraulic tank slowly to release the internal pressure of the hydrau- lic tank. 1) Remove the top cover of the control valve and open the pump room cover.
2) Remove oil pressure pickup plugs (1) and (2). (1): Pump discharge pressure pickup plug (at top of control valve) The drawing shows the LS valve output pressure side. PC130-7 20-129 (1) Symbol Part No. Part name L 1 799-101-5002 Hydraulic tester 790-261-1203 Digital hydraulic tester 2 799-101-5220 Nipple (10 x 1.25 mm) 07002-11023 O-ring 3 799-400-2701 Differential pressure gauge