Komatsu — 20-201--.pdf

TESTING AND ADJUSTING TESTING AND ADJUSTING OIL PRESSURE IN PUMP LS CONTROL CIRCUIT 4) Run the engine and heighten the hydraulic oil temperature to 45 – 55°C, and then push up the track shoe on either side with the work equipment. 6) After finishing measurement, remove the measuring instruments and return the removed parts. 5) While running the engine at high idling, mea- sure the pump discharge pressure and LS valve output pressure (servo piston inlet pressure) simultaneously. Working mode: A Travel speed switch: Hi Work equipment, swing, and travel cir- cuits: Set all levers in neutral and run track shoe on one side idle. 2.

Measuring LS differential pressure a Measure the pump discharge pressure and LS pressure (actuator load pressure) simul- taneously and calculate the difference between them. 1) Remove the top cover of the control valve and remove oil pressure pickup plugs (1) and (3). (1): Pump discharge pressure pickup plug (3): LS pressure pickup plug k Checking the safety around the machine, run the track shoe pushed up idle. a Method of judgment: If the pump discharge pressure and LS valve output pressure (servo piston out- put pressure) are in the following ratio, they are normal.

20-130 PC130-7 (1) Pum discha Travel lever press MP p LS valve rge output R ure pressure a {kg/cm2} atio of oil pres- sure 2.9±0 Neutral {30± .5 2.9±0.5 5} {30±5} Almost same pressure (1:1) Full (Idle 7.8±2 running) {80±2 .0 4.4±1.0 0} {45±10} Almost 3/5 (1:0.6)