TESTING AND ADJUSTING TESTING AND ADJUSTING OIL PRESSURE IN PUMP LS CONTROL CIRCUIT 2) Install nipple L2 and connect it to the oil pressure gauge of hydraulic tester L1 . a When using differential pressure gauge: Connect the pump discharge pressure to the high pressure side (back side) and connect the LS pressure to the low pres- sure side (lower side). Since the differential pressure gauge needs a 12-V power source, connect it to a battery. a When using oil pressure gauge: Use the oil pressure gauge of 58.8 MPa {600 kg/cm 2 }. Since the differential pressure is about 2.9 MPa {30 kg/cm 2 } at maximum, mea- sure it by installing the same gauge to the pickup plugs alternately.

4) While running the engine at high idling, mea- sure the pump discharge pressure and LS valve output pressure (servo piston inlet pressure) simultaneously. Working mode: A Travel speed switch: Hi Work equipment, swing, and travel cir- cuits: Set all levers in neutral and run track shoe on one side idle. k Checking the safety around the machine, run the track shoe pushed up idle. a Calculation of LS differential pressure (when oil pressure gauge is used): LS differential pressure = Pump dis- charge pressure - LS pressure a If the LS differential pressure is as fol- lows, it is normal.

3) Run the engine and heighten the hydraulic oil temperature to 45 – 55°C, and then push up the track shoe on either side with the work equipment. 5) After finishing measurement, remove the measuring instruments and return the removed parts. PC130-7 20-131 (1) Travel lever LS differential pressure Neutral LS differential pressure in neutral (See standard values table) Full (Idle running) Specified LS differential pressure (See standard values table)