TESTING AND ADJUSTING TESTING AND ADJUSTING OIL PRESSURE IN PUMP LS CONTROL CIRCUIT ADJUSTING Adjusting LS valve 6. After finishing adjustment, check that the pres- sure is normal according to the above described procedure. a If the LS differential pressure is abnormal, adjust LS valve (4) according to the procedure shown below. a The figure shows the hydraulic pump seen from the front side of the machine. 1. Loosen hose sleeve nut (4). 2. Fixing plug (5), loosen locknut (6). 3. Turn plug (5) to adjust the differential pressure. a If the plug is turned to the right, the differential pres- sure rises. turned to the left, the differential pressure lowers.
a Quantity of adjustment (LS differential pres- sure) per turn of plug: 1,304 kPa {13.3 kg/cm 2 } a Tighten the hose sleeve nut (4) temporarily and turn the plug, while checking the LS dif- ferential pressure. 4. Fixing plug (5), tighten locknut (6). 3 Locknut: 98 – 122.5 Nm {10 – 12.5 kgm} 5. Tighten hose sleeve nut (4). 20-132 PC130-7 (1)