TESTING AND ADJUSTING MEASURING SOLENOID VALVE OUTPUT PRESSURE MEASURING SOLENOID VALVE OUTPUT PRESSURE a Use the oil pressure gauges of 5.9 MPa {60 kg/cm 2 }. a The figure shows the measuring instruments connected to the outlet hose of the 2-stage relief solenoid valve. a Measuring instruments for solenoid valve output pressure a Before measuring the solenoid valve output pressure, check that the basic pressure in the control circuit is normal. k Lower the work equipment to the ground and stop the engine.
Operate the control levers several times to release the residual pressure in the piping, and then loosen the oil filler cap of the hydraulic tank slowly to release the internal pressure of the hydraulic tank. 4. Run the engine and heighten the hydraulic oil temperature to 45 – 55°C. 1. Remove the undercover of the control valve and disconnect outlet hoses (1) – (4) of the solenoid valves to be measured. a Since outlet hose (4) of the PPC pressure lock solenoid valve has a quick coupler, measure the output pressure on the PPC valve side. 5. Run the engine at high idling, operate the control levers and switches to turn the solenoid valve ON or OFF, and measure the oil pressure.
a For the conditions for turning the solenoid valve ON and OFF, see the operations table of each solenoid valve. a The operating condition of the solenoid valve can be also checked with the monitoring function [02] of the monitor panel (excluding the PPC pressure lock solenoid valve). a If the output pressure is as follows, the sole- noid valve is normal. 2. Install adapter M2 and connect the disconnected hose again. 3. Install nipple [1] of hydraulic tester M1 and con- nect it to hydraulic gauge [2]. PC130-7 20-133 (1) Symbol Part No. Part name M 1 799-101-5002 Hydraulic tester 790-261-1203 Digital hydraulic tester 2 799-401-3100 Adapter (Size 02) No.
Solenoid valve to be measured 1 2-stage relief solenoid valve 2 Swing holding brake solenoid valve 3 Travel speed solenoid valve 4 PPC pressure lock solenoid valve Solenoid valve Output pressure OFF (Deenergized) 0 MPa {0kg/cm2} ON (Energized) Almost same as control basic pressure (See standard values table)