TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL 3. Function of displaying error code [01] With this function, you can check the error code of a trouble which is occurring at present or has occurred in the past. 3) Information displayed in display section and service meter section 2 (When error code is not recorded) If an error code is not recorded, display sec- tion (1) and service meter section (2) display as shown below. 1) Selecting and executing function i) Select menu No. [01] in the menu selec- tion mode. ii) Press set switch (5) to execute this func- tion.
2) Information displayed in display section and service meter section 1 (When error code is recorded) If an error code is recorded, the following information is displayed in display section (1) and service meter section (2). (a): Error code (b): Service meter reading increased after trouble occurred (c): Mark [E] to indicate that trouble is occur- ring at present a Mark [E] to indicate that a trouble is occurring at present indicates that the error code is being detected now. It is not displayed if the trouble has been repaired or the error code is not detected. a For the error codes which the monitor panel and governor and pump controller can detect, see the "Error codes table".
4) Number of recorded error codes and display order of them This function can record up to 20 error codes, which are displayed in order from the latest one. a If a new trouble occurs while 20 error codes are recorded, the oldest error code is deleted and the error code of the new trouble is recorded. 20-152 PC130-7 (1)