Komatsu — 20-201--.pdf

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL Operation and display of service menu 3) Selecting menu Holding caution buzzer stop switch (3), operate working mode selector switches (7) and (8) to select a menu you will use. UP switch (7): Menu No. increases. DOWN switch (8): Menu No. decreases. How to select service menu a When using the general functions in the service menu, perform the following switch operation to change the screen of the monitor panel. 3. Function of displaying error code [01] 4. Monitoring function [02] 5. Function of adjusting governor [03] 6. Function of selecting maintenance period [04] 7.

Function of selecting default working mode [05] 1) Operating switches Holding caution buzzer stop switch (3), hold auto decelerator switch (4) for 2.5 seconds. 4) Executing menu Select a menu you will use and press set switch (5), and the menu is executed. 2) Displaying display section and service meter section If the switches are operated as shown above, the first menu No. [01] (Monitoring function) is dis- played in service meter section (2). a Nothing is displayed in display section (1). 5) Finishing service menu Holding caution buzzer stop switch (3), hold auto decelerator switch (4) for 2.5 seconds (similarly to the selecting operation).

a The service menu is finished and the ordi- nary screen appears. a The service menu can be also finished by turning the starting switch OFF while the ser- vice menu is selected. (In this case, the ordi- nary screen appears when the starting switch is turned ON again.) a To use the special functions in the service menu, you must operate the switches differently from the above. See details of each menu. 8. Function of adjusting service meter 9. Special function of monitoring replace- ment of engine oil PC130-7 20-151 (1) Menu No.

Service menu (Excluding special functions) 01 Function of displaying error code 02 Monitoring function 03 Function of adjusting governor 04 Function of selecting maintenance period 05 Function of selecting default working mode