Komatsu — 20-201--.pdf

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL 20-158 PC130-7 (1) Code Monitoring item Unit Remarks 024 (Unused) — 027 Input condition of model selection signal a Model selection 1 (Connected to ground) (6bit) b Model selection 2 (Connected to ground) (6bit) c Model selection 3 (Connected to ground) (6bit) d Model selection 4 (Connected to ground) (6bit) e Model selection 5 (Connected to ground) (6bit) f (Unused) (6bit) 030 Fuel control dial input voltage 10mV 031 Governor potentiometer input voltage 10mV 032 Controller power source voltage 100mV 033 Governor motor phase A output current 10mA 034 Governor motor phase B output current 10mA 035 Battery relay BR output voltage 100mV 036 Input condition of signal a (Unused) (6bit) b (Unused) (6bit) c (Unused) (6bit) d (Unused) (6bit) e Starting switch signal C (START) (6bit) f (Unused) (6bit) 037 Output condition of signal a Battery relay (DRIVEN) (6bit) b (Unused) (6bit) c (Unused) (6bit) d (Unused) (6bit) e (Unused) (6bit) f (Unused) (6bit) 041 Engine coolant sensor input voltage 10mV 042 Fuel level sensor input voltage 10mV 043 Alternator input voltage 10mV 044 (Unused) — 045 Input condition 4 of switch a Starting switch signal ACC (ON) (6bit) b Starting switch signal C (START) (6bit) c Starting switch signal R1 (HEAT) (6bit) d Lamp switch (ON) (6bit) e (Unused) (6bit) f (Unused) (6bit)