TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL 8. Function of adjusting service meter When the monitor panel is replaced, you can set its service meter to the reading at the time of replacement. 1) How to select this function i) Set swing lock switch (9) in the LOCK position. a While using this function, keep the swing lock switch in the LOCK posi- tion. ii) Holding caution buzzer stop switch (3), press the switches in the following order. 1. Travel speed shifting switch (6) 2. Set switch (5) 3. Auto decelerator switch (4) 4.
Working mode selector (UP) switch (7) 3) Selecting figure to be corrected Holding caution buzzer stop switch (3), press auto decelerator switch (4) and set switch (5) simultaneously, and the figure on the left side starts flashing. a If the above operation is performed while the figure at the left end is flashing, the figure at the right end starts flashing. 4) Increasing or decreasing figure to be cor- rected Holding caution buzzer stop switch (3), oper- ate auto decelerator switch (4) and working mode selector switches (7) and (8). UP switch (7): Figure increases. DOWN switch (8): Figure decreases. a If the figure at a position does not need to be corrected, input "0".
2) Information displayed in display section and service meter section The currently set service meter information is displayed in service meter section (2) and only the figure selected for correction flashes (When a new monitor panel is installed, 0h is displayed). a Nothing is displayed in display section (1). a When this function is selected, the figure at the right end is selected automatically and it flashes. 5) How to finish function Perform the operation of selecting this func- tion. a If the service meter reading is increased, the new value is saved. a If the service meter reading is decreased, the new value is not accepted, but the caution buzzer sounds 3 times. 20-164 PC130-7 (1)