Komatsu — CLEAN INSIDE OF COOLING SYSTEM

. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE 4 - 23 3. Set a container in position to c atch the drain antifreeze mixture, then open the drain valve (3 ) at the radiator lower tank and nd drain the coolant. drain plug (4) of the engine, a 4. After draining the coolant, clos e drain plugs (3) and (4), and fill with tap water. 5. When the radiator is full, start the engine, and run it at low idle. Keep the engine running at l coolant temperature reaches 6. Stop the engine, open drain water. 7. After draining the water, clean the cooling system with cleaning agent. For the cleaning method, see the instructions for the cleaning agent. 8. Close drain plugs (3) and (4). 9.

Replace the corrosion resistor , then set valve (1) to the OPEN position. For details of the procedure fo r replacing the corrosion resistor, see Section "REPLACE CARTRIDGE (PAGE 4-59)". 10. Add coolant mixed with antifr Decide the proportions of antif reeze and water according to the table for the mixing rate of water and antifreeze. 11. To bleed the air from the cooli ng system, run the engine at low idle for 5 minutes, and for a further 5 minut es at high idle. (When doing this, le 12. Open drain plug (6) to drain wash the inside of the sub tan 13. coolant level is between the F Stop the engine, wait for appr ULL and LOW marks. ox.

3 minutes, then add coolant until the coolant level is near the coolant filler port, and tighten the cap. Check the coolant level and add coolant if necessary. until the coolant level is near t he coolant filler port, and tighten the cap. Check the coolant le vel and add coolant if necessary.