Komatsu — EXTERNAL POWER SOURCE TYPE ENGINE PREHEATING HEATER

. OPERATION EXPLANATION OF COMPONENTS not mean that any cable can be used. Manufacture the cable as follows. 1) For the wiring, purchase three-core chloroprene sheath cab tire cable locally. 5 to 8 mm 2 (0.0078 to 0.0124 in 2 ). withstand 3000 volts for 1 minute. To prevent any drop in voltage, make the length less than 30 m (98 ft 5 in). of the cable to its respective contact. 3 - 67 4. Manufacturing extern ource input cable must be manufactured local ly to match the local conditions. This oss-sectional area of one core should resistance function, it should be able sis input side plug (shipped as individual part) 175-06-37871 to th e tip of the cable.

ree contacts and each contact i s marked with a symbol. Connect e ach of the 3 core ng, solder each core wire to its rt-circuiting through the conduc tor, insulate the soldered portion with a rubber tube or t No. 175-06-37871 for the plu g is used, it will be impossible to connect to th e external power inp