Komatsu — STARTING MACHINE AFTER LONG-TERM STORAGE

. OPERATION LONG-TERM STORAGE LONG-TERM STORAGE DURING STORAGE WARNING AFTER STORAGE 3 - 174 BEFORE STORAGE r a long time (more than one month), do as follows. When putting the machine in storage fo r a long time (more than one month), do as follows. Clean and wash all parts, then store t he machine indoors. If the machine has to be store d outdoors, s elect l evel ground and cover the machine with c anvas. vents moisture from collecting. torage. aulic cylinder piston rod with grease. of the battery and cover it, or remove it from the machine and store it Completely fill the fuel tank.

This pre Lubricate and change the oil before s Coat the exposed portion of the hydr Disconnect the negative terminals separately. Place all control levers at the neutral position, set the work equipment lock lever and parking brake le ver to the lock position, and set the fuel control dial to the low idling position. To prevent rust, fill with Komatsu gen uine super coolant to give a density of at least 30% for th e engin e coolant. If it is necessary to perform the rust-preventi on operation while the machine is indoors, open the doors and windows to improve ventilation and prevent gas poisoning.

During storage, operate and move the machine for a short distance once a month so that a new film of o il will coat moving parts. At the same time, also charge the battery. wipe off all the grease from the hydraulic cylinder rods. When operating the work equipment, wipe off all the grease from the hydraulic cylinder r If the machine is equipped with an air conditioner, operate the air conditioner for 3 to 5 minute s once a mon th to lubricateall parts of the air conditioner check the refrigerant level twice a ye compressor. Always run the engine at low idle when doin g this. I n addition, ar.

NOTICE If the machine has been stored without carr ying out the monthly rust-prevention operation, consult your Komatsu distributor before using it. When using the machine after long-term storage, do as follows before using it. ic cylinder rods. oints. Wipe off the grease from the hydraul Add oil and grease at all lubrication p When the machine is stored for a long period, moisture in the air will mix with the oil. Check the o il before and after starting the engine. If there is water in the oil, change all the oil. STARTING MACHINE AFTER LO NG-TERM STORAGE When starting the engine after the machi ne has been in storage for a long period, carry out the warming-up operation thoroughly.

For details, see the proced ure in "WARMING UP OPERATIONS (PAGE 3-119)".