Kubota — Battery Service

60 Replacing Hydraulic Return Filter Element (fi rst replacement after 250 service hours) 3 CAUTION To avoid personal injury: Remove the oil fi lter only after the oil in the hydraulic tank has cooled down. Battery Service 3 DANGER To avoid the possibility of a battery explosion: For refi llable type battery, follow the instructions below. Do not use or charge the refi llable type battery if the fl uid level is below the LOWER (lower limit level) mark. Otherwise, the battery component parts may prematurely deteriorate, which may shorten the battery's service life or cause an explosion.

Check the fl uid level regularly and add distilled water as required so that the fl uid level is between the UPPER and LOWER levels. 3 CAUTION To avoid personal injury: Batteries contain sulphuric acid which can cause severe burns. Avoid all contact with skin, eyes or clothing. Antidote - External: Rinse with plenty of water. Internal: Drink large quantities of water or milk. Follow with milk of magnesia, beaten egg or vegetable oil. Call a physician immediately. Eyes: Rinse with plenty of water for 15 minutes and get prompt medical attention. Keep batteries out of the reach of children.

Before inspection or dismounting the battery, be sure to turn of the engine and turn the starter switch to the "OFF" position. When removing the battery, always disconnect the negative ground cable fi rst. The reverse when installing a battery, always connect the ground cable last. This prevents a possible explosion caused by sparks. Always wear eye protection when working with the battery. Contact your KUBOTA dealer for details. (1) Return fi lter IMPORTANT: Always check the oil level when replacing the fi lter.